City Of Chicago Stationary Engineers License Renewal

No State Jurisdictional Boiler & Refrigeration Operator's License Law at this time.

Jun 07, 2018 As of June 01, 2014 in order to renew your Engineer's License, you must renew it through the website of You must print out the form and mail as per instructions with a check. 26 May 2017 Renew City Of Chicago Stationary Engineers License. 05/26/ You must print out the form and mail as per instructions with a check. CITY OF CHICAGO TESTING AND LICENSING. Licensing and License Renewals Please click here to view F.A.Q.' S for City of Chicago. Click here for Trade Licensing Renewal Information Click here to view City of Chicago Stationary Engineers Exam Schedule Click here to view City of Chicago Stationary Engineers online exam application. License No.: 301 - STATIONARY ENGINEER. 310 - ELEVATOR City of Chicago Trade Licenses & Examinations. BOX Stationary Engineers Advancement Program. Local 399 is proud of its reputation as a Illinois Pool Study Guide Stationary Engineer License Renewal Info 19 Jun 2014 The City of Chicago has hired Continental Testing to handle all aspect of the.


City of Chicago

Chicago Department of Buildings
Bureau of Licensing & Registration
120 N. Racine Ave.
Chicago, IL 60607

Contact the Department of Buildings Licensing and Registration at (312) 743-9061.

The City of Chicago has 1 license level (one size fits all license):

  • Chicago Stationary Engineer

To qualify for a City of Chicago Stationary Engineer's license exam the following must be submitted.

  1. Must be 21 years of age
  2. Letter of recommendation to include on a letter (on company stationary) from their current or former employer’s “chief stationary engineer” vouching for the applicant. Include the chief engineer’s license number.
  3. The letter must verify the dates of employment
  4. Letter needs to include equipment’s steam output per hour, operating pressure, heating surface and maximum allowable work pressure shall be identified, and recite the applicant’s duties and responsibilities.
  5. Must have a minimum of two years’ experience in operation of high pressure boilers.

Decatur

Decatur Board of Examiners, Steam Engineers
Decatur, IL 60602

At this time this License law may no longer be Active.
Information was not clear when obtained.

City of chicago department of buildings stationary engineer license renewal

The City of Decatur has 2 licensing levels:

  1. Decatur 1st Grade Engineer
  2. Decatur 2nd Grade Engineer

East Saint Louis

East Saint Louis City Hall, Boiler Inspector
East St Louis, IL 66201

At this time this License law may no longer be active. Information was not clear when obtained.

Elgin

Elgin City Hall
150 Dexter Court
Elgin, IL 60120-5650

License

The City of Elgin has 2 licensing levels:

  1. Elgin Stationary Engineer
  2. Elgin Boiler Fireman


City of Evanston, IL

Strangly the Evanston Municipal Code no longer addresses licensing and was refered to the Fire Chief (Title 4-3), and does not in any way address licensing for STATIONARY ENGINEERS, BOILER OR WATER TENDERS in it code or statute.

However, the City Manager has instructed the Evanston Building & Zoning Department at 555 Lincoln Street, Evanston, IL 60201to give a STATIONARY ENGINEERS, BOILER OR WATER TENDERS examination to applicants for a license as stationary operating engineers or boiler and water tenders and references the Evanston, Illinois - Code of Ordinances: Title 4-3.

I get the impression they will accept recprocal licensure and you will need to contact Dave Stoneback, Director of Utilities or Dennis Marino, Assistant Director, Planning and Zoning at Building and Zoning Division - 847-866-2932

Peoria

Peoria City Hall
419 Fulton
Peoria, IL 61602

Local residency is not required to apply for a license. Licenses from other jurisdictions recognized for experience.

The City of Peoria has 3 licensing levels:

  1. Peoria 1st Class Stationary Engineer
  2. Peoria 2nd Class Stationary Engineer
  3. Peoria Boiler Tender

For supervising electricians, electrical contractors, mason contractors, plumber's apprentices, plumbers, and plumbing contractors

You may want to print out these instructions so that you can refer to them as you navigate the online renewal system. After you have read these instructions, go to the bottom of this page and click 'Get Started Online.'

Cached

Step 1. Log In.

You will first be asked to log in to your account.

High Pressure Boiler Operating Engineer License Information

If your password or username are entered incorrectly or do not match what you were given (password) or created (username) when you created your account, you will be unable to log in or to renew your license.

If you have not created an account before, click on the link in the middle of the page: ”New to the system? Click here to get started.”

If you have already created an account, skip to Step 2.

If you have created an account before but have forgotten your password, click the link on the login page to retieve your password.

Step 1A. Create Account.

You will be asked: “Are you a licensed individual or contractor….?”

Select 'Yes.'

Next, you will be asked to select your Contractor Type from a drop down menu.

If you are a licensed Apprentice Plumber, Plumber (Journeyman), or Plumbing Contractor select Plumbing Contractor.

If you are a Mason with an A, B, or C license select Mason Contractor.

If you are a licensed Supervising Electrician or Electrical Contractor select Electrical Contractor.

Next, you will be asked to enter your license number. You must enter the correct number and prefix. The following are the correct prefixes for each license type:

License TypeCorrect PrefixExample

Don’t Use

Apprentice Plumber A (and your number)

A12345

PLA
Plumber (Journeyman)
J J12345 PL
Plumbing Contractor BC BC12345 PL
Supervising Electrician
SE SE1234 E
Electrical Contractor
ECC ECC12345 E
Mason Contractor
MC MC1234 M

Next, you will be asked for your daytime phone number. The phone number you enter must exactly match the phone number in your existing trade license account information. If you enter in a phone number that is different from the previous number you gave to the Department, then the computer system will not be able to verify that you are currently licensed in our system and will not be able to complete your log in or renewal.

Click 'Next.'

You will then be allowed to create your own user name. It is case sensitive. Please write down your username __________________________________.

You will be required to provide an email address. If you are currently using AOL or COMCAST as your email provider, you may experience difficulty or not be able to renew using the online trade licensing renewal system. You can use Yahoo, Google, Hotmail, Gmail or any other free internet provider to set up an email address to have your password sent to that account.

Select a security question from a drop down menu. The online renewal system will automatically email you a password for your use to access the renewal process.

The Password may contain letters and numbers, and some of the letters may be capitalized and some may be lowercase. Please note the password is case sensitive: Example - GB33mxDN42, Once you have logged into your account, you can always click 'Update Account' on the left side of the screen to change the password to something that you can remember.

Please write down your username, the security question answer you provide, and your password. Please keep this information in your records for future reference should you wish to access your account.

Step 2. Enter Renewal Data.

Follow the on-screen steps for your license type. Use the online system to pay the required renewal fee.

City of Chicago :: Trades

Step 3. Print Proof of Renewal.

Print or save a copy of the confirmation page at the end of the renewal process.

City Of Chicago Stationary Engineers License Renewal

Plumbing Contractors, Mason Contractors and Supervising Electricians should print their CERTIFICATE before exiting. To do so, look for the small print icon under “Action”.

City Of Chicago Department Of Buildings Stationary Engineer License Renewal

For license types that receive a photo ID card, ID's will be placed in the mail shortly after renewing.

Chicago Plumbing License Renewal

If you have any questions about renwals, please call Continental Testing Services at 800-359-1313.